What LEED Building Design and Construction project type should exclude weekend transit service from the transit service level calculations for Location and Transportation Credit, Access to Quality Transit, if the project occupants do not commute to the building during weekends?
Correct : B
Data centers are buildings that house computer systems and associated components, such as servers, storage devices, and network equipment. They typically operate 24/7 and do not have regular commuting patterns of occupants. Therefore, they can exclude weekend transit service from the transit service level calculations for the Location and Transportation Credit, Access to Quality Transit12. This credit aims to encourage development in locations that are served by high-quality transit, which reduces greenhouse gas emissions, transportation costs, and automobile dependence.
Start a Discussions
In order for a product to contribute to Materials and Resources Credit, Building Product Disclosure and Optimization, Environmental Product Declarations, Option 1. Environmental Product Declaration, the product needs to be
Correct : D
The correct answer is D. critically reviewed life-cycle assessment conforming to ISO 14044. This is because:
* Option 1 of this credit requires the use of products that have environmental product declarations (EPDs), which are documents that provide information about the environmental impact of a product throughout its life cycle1.
* EPDs are based on life-cycle assessments (LCAs), which are systematic analyses of the environmental aspects and potential impacts of a product from raw material extraction to disposal2.
* LCAs must conform to the international standard ISO 14044, which specifies the principles and framework for conducting and reporting LCAs3. LCAs must also be critically reviewed by an independent panel of experts to ensure their validity and reliability4.
* The other options are not relevant for this credit. FSC certification is a label that indicates that a wood product comes from a well-managed forest5. Cradle-to-cradle certification is a label that indicates that a product is designed for circular economy, with minimal waste and toxicity. CSR is a report that discloses the social and environmental performance of a company.
Start a Discussions
When the project occupancy is not known, which method is recommended?
Correct : A
This method is recommended when the project occupancy is not known, because it provides the default occupant density values for various space types, such as offices, classrooms, retail, and restaurants1. These values are based on the typical or average occupancy of similar spaces, and can be used to estimate the ventilation requirements and energy performance of the project2.
Start a Discussions
In the energy modeling of a building envelope, which of the following U-values should be considered as an assembly U-value?
Correct : A
The assembly U-value of a building envelope component is the overall rate of heat transfer through that component, taking into account the different materials and layers that make up the component. For example, the assembly U-value of a wall would include the effects of the insulation, framing, sheathing, cladding, air films, etc. The assembly U-value is different from the material U-value, which is the rate of heat transfer through a single material. For example, the material U-value of steel is much higher than the material U-value of glass, but the assembly U-value of a steel-framed window may be lower than the assembly U-value of a glass curtain wall, depending on the other factors involved.
Start a Discussions
In Sustainable Sites Credit, Light Pollution Reduction, which factor is included in the lamp lumen uplight calculation?
Correct : D
This factor is included in the lamp lumen uplight calculation, because it represents the amount of light that is emitted downward by the fixture, which does not contribute to light pollution1. The lamp lumen uplight calculation is used to determine the percentage of total luminaire lumens emitted above horizontal, which must not exceed the maximum allowed values for each lighting zone2.
Start a Discussions