A customer currently operates a legacy iSCSI storage environment that is connected to network switches with several Windows hosts. As part of an upcoming NetApp ONTAP software upgrade, an engineer needs to verify compatibility.
Which two NetApp tools would help the engineer assess the environment? (Choose two.)
Correct : B, C
To verify compatibility in an iSCSI storage environment before a NetApp ONTAP software upgrade, the following tools are recommended:
Interoperability Matrix Tool (IMT): This tool helps verify the compatibility of different components, including network switches, hosts, and storage systems, ensuring that the planned upgrade will be supported.
Active IQ OneCollect: This tool collects comprehensive configuration and performance data from the storage environment, which can be used to assess the current setup and identify any compatibility issues before the upgrade.
For further details, refer to:
NetApp Interoperability Matrix Tool
Active IQ OneCollect Documentation
Start a Discussions
A storage engineer in SAN environment needs to Identify FC ports using the company-wide naming policy. Which command will accomplish this task?
Correct : A
The vserver fcp wwpn-alias set command is used to set or modify the World Wide Port Name (WWPN) aliases for Fibre Channel (FC) ports in a NetApp ONTAP environment. This command allows you to apply a company-wide naming policy to FC ports, ensuring consistent and easily identifiable naming conventions across your storage infrastructure.
For further details, you can refer to:
NetApp Documentation on FC Management
NetApp Community Discussion on WWPN Aliases
Start a Discussions
When using FCP, what is the minimum number of FC switches needed to redundantly attach three ESXi hosts?
Correct : C
When using Fibre Channel Protocol (FCP), the minimum number of FC switches needed to redundantly attach three ESXi hosts is 2. This setup ensures that each host has multiple paths to the storage, providing high availability and fault tolerance. Each ESXi host should be connected to both switches, allowing for continuous operation even if one switch fails.
For more information, refer to:
NetApp Documentation on FC Switch Configurations
NetApp Community Discussion on Redundant FC Setup
Start a Discussions
An administrator creates a new volume and a LUN for an SAN-connected application that uses snapshots. The application has fast-growing data that is constantly being populated and deleted afterwards.
Which option can be set to manage the space automatically?
Correct : A
To manage space automatically for a volume containing a LUN with fast-growing data, enabling automatic resizing on the volume is recommended. This feature allows the volume to grow dynamically as needed, accommodating the fluctuating data size without manual intervention. This helps in managing storage efficiently and ensures that the application has the required space.
For further details, refer to:
NetApp Documentation on Volume Management
NetApp Community Discussion on Automatic Resizing
Start a Discussions
A site survey has been conducted for an installation of a switchless HA pair with two NetApp DS224C shelves in the customer's already populated rack.
Which of the following two need to be verified to ensure a successful deployment? (Choose two.)
Correct : B, C
For a successful deployment of a switchless HA pair with two NetApp DS224C shelves in an already populated rack, it is crucial to verify:
Rack units: Ensure that there are enough rack units available to accommodate the new shelves and any associated equipment. Proper planning of space in the rack is essential for a neat and functional setup.
Power connections: Verify that there are sufficient and appropriately rated power connections available. Ensuring proper power distribution and redundancy is critical for the reliability and uptime of the storage system.
For more details, refer to:
NetApp Documentation on Rack Installation
NetApp Community Discussion on Power Connections
Start a Discussions